COMTRAXX® CP9xx

Device features
• Display sizes 7″, 15″ and 24″ with tempered and anti-reflective glass
• Easy to clean and disinfect, degree of protection IP54
• Screwless mounted front plate
• User-friendly touch-sensitive monitoring system for medical locations and other applications
• Particularly simple operation
• Additional information for medical and technical personnel
• Visual and acoustic notification in the event of an alarm
• Clear menu structure with intuitive interactive images
• Clearly labelled safety functions
• Silent due to operation without fan
• High-quality display with excellent contrast, high resolution and wide viewing angle
• Possibility of graphical integration of building plans or status displays in photo quality
• Easy integration of external equipment like charging stations for operating theatre table controls and intercom systems with front foil
• Simple conversion and expansion with minimal service interruptions

Product Overview

Description

Intended use
Remote alarm indicator and operator panels CP9xx display alarms, measured values and
states of devices. These include, for example:
• All Bender devices with BMS bus or BCOM interface
• Bender devices (PEM, energy meters,…) with Modbus RTU or Modbus TCP interface
• Other devices with Modbus RTU or Modbus TCP interface
In addition, the data is available via Modbus TCP, Modbus RTU, SNMP, MQTT and
PROFINET protocols. This allows coupling to a higher-level building control system as
well as visualisation and evaluation using standard web browsers.
Operation and settings are made via the COMTRAXX® user interface integrated in the
device.
Any other use than that described in this manual is regarded as improper.
Applications (Operating theatres, Critical care areas, etc)
  • Medical IT, UPS & Battery Back Up Power Systems
  • Optimal visualisation on the display tailored to the user
  • Integration of all compatible Bender products (ISOMETER®, ATICS®, RCMS, EDS, LINETRAXX® and MEDICS® systems, universal measuring devices and energy meters)
  • Individual instructions in case of alarms
  • Selective notification to various users in case of alarms
  • Control and regulation of systems such as air conditioning or blinds control.
  • Ventilation, Ultra Clean Ventilation & Building Management Systems
  • General & surgical lighting
Optional accessories
• The remote I/O system offers numerous options for integrating digital and analogue I/Os with different operating voltages, capacities, measurement signals or special functions into the alarm indicator and operator panel.
• Communication with building management systems via common interfaces such as
Modbus TCP, Modbus RTU, PROFIBUS, KNX, LonWorks, Sercos interface, InterBus, Dali,
CANopen, EtherNet/IP, CC-Link, DeviceNet, BACnet, PROFINET.
The result is an all-round system that is both modular and flexible and can thus be adapted, expanded or connected to new technologies.
Other project-specific versions with foil front or with additional internal components
available on request:
• Charging trays for operating theatre table remote controls
• Intercom systems
• Operating theatre light controls
• Programmable backlit keypads
• Digital/Analogue inputs/outputs for installation in panel enclosures or control cabinets
• Data coupling to third-party systems
• Project-specific installation enclosures
• Integration of third-party equipment
• Antibacterial or highly transparent foil options available
• Replacement of existing panels (retrofitting)
Interfaces
CP9xx communicate with the devices and systems assigned via
various interfaces:
• Internal BMS bus (RS-485) for Bender systems such as EDS46…/49…, RCMS46…/49… and MEDICS®.
CP9xx can be operated as a master or as a slave. When operated as a master,
requests are answered more quickly. The devices can only be
operated on the internal BMS bus.
• BCOM (Ethernet) for new and future Bender systems, such as ISOMETER® iso685-D.
• Modbus RTU (RS-485)
CP9xx when operated as a master for Bender devices PEM…
with restricted functionality (full functionality of PEM…5 only
via Modbus TCP).
• Modbus TCP (Ethernet) for Bender devices PEM…5